Model: APVF

Type: Oh3 – API 610
Vertical In-line
Process Pumps

TECHNICAL DATA:
– Max. Capacity up to 1500 m³/h
– Max. Operating Pressure up to 50 bar
– Max. Temperature from -100 up to 450°C

Model: VCH/VCTM

Type: VS6 (Also available in accordance with API 610)
Vertical Double-casing (can) Diffuser Pumps

TECHNICAL DATA:
– Max. Capacity up to 1800 m³/h / up to 500 m³/h
– Max. Operating Pressure up to 40 bar / up to 150 bar
– Max. Temperature from -100 up to 350°C / from -100 up to 180°C

Model: VTH

Type: VS1 (Also available in accordance with API 610)
Vertical Turbine / Mixed Flow Pumps

TECHNICAL DATA
– Max. Capacity up to 10000 m³/h
– Max. Operating Pressure up to 40 bar
– Max. Temperature up to 150°C

Model: HPV/VW

Type: VS4 (Also available in accordance with API 610)
Vertical Sump Pumps

TECHNICAL DATA
– Max. Capacity up to 1500 m³/h
– Max. Operating Pressure up to 16 bar
– Max. Temperature up to 300°C

Model: IPV

Type: OH4
Vertical In-line Process Pumps

TECHNICAL DATA
– Max. Capacity up to 180 m³/h
– Max. Operating Pressure up to 25 bar
– Max. Temperature from -40 up to 140°C